Anglia Range (Export)
14th January 1963Heater
Control Knobs
New
"Anglia" Saloon (1959 onwards) and
Estate Cars
As an additional precaution
against the possibility of the heater control
knob securing screw becoming loose, a small
quantity of jointing compound, Part No EM-4G-52,
is now used on the thread of each screw in
production. It is suggested that a similar
practice be adopted in service if the above
condition is experienced, or if at any time a
screw is replaced.
To obtain the best results
from this jointing compound the following
precautions must be taken :-
1. All traces of grease,
oil and dirt must be removed from the screws and
the threaded holes into which they fit and
therefore they should be cleaned thoroughly with
trichlorethylene or any other suitable cleaning
solvent and allowed to dry before applying the
sealer.
2. A thin line of sealer
along the threads of each screw will be
sufficient to obtain a firm fixing. No advantage
will be gained by applying a greater quantity -
it will merely increase the "setting"
time and make the screws more difficult to
remove.
3. Fit the screws
immediately the sealer has been applied.

|